SY 9223 PLC AAN – PLC Bypass
The PLC bypass SY 9223 PLC AAN can be used in AC and DC systems.
Circuit and design comply with the standard CISPR 25, Annex E.4.3, Figure E.7.
Balanced-to-Unbalanced Transformers
The PLC bypass SY 9223 PLC AAN can be used in AC and DC systems.
Circuit and design comply with the standard CISPR 25, Annex E.4.3, Figure E.7.
The SY9223-50-BNC is a wideband-balun designed for reflection and transmission measurements of symmetrical EuTs. To increase reproducibility of measurements the symmetrical port is also shielded. This balun is not galvanically isolated. Frequency Range: 9 kHz … 150 MHz Nominal Impedance:…
The SY 9223-439 transformer causes a voltage transformation Uin / Uout = 1 / 2 and is designed for operation with hand-held field coil – e.g. FESP 5132 when performing tests according to IEC 61000-4-39. For this purpose, the field…
The SY 9223-7637-4 is a balanced-to-unbalanced transformer (abbr. balun) – transforming an unsymmetrical RF signal into a symmetrical one while not transforming the impedance. A bidirectional direction of operation is possible. The SY 9223-7637-4 has a low insertion loss, a…
The balun transforms an unsymmetrical signal at a 50 Ω source impedance into a galvanically isolated symmetrical signal at 100 Ω impedance in a wide frequency range. Thus measurements on symmetrical quadripoles which have an impedance of 100 Ω can…
The balun transforms an unsymmetrical signal at a 50 Ω source impedance into a galvanically isolated symmetrical signal at 120 Ω impedance in a wide frequency range. Thus measurements on symmetrical quadripoles which have an impedance of 120 Ω can…
The balanced to unbalanced transformer SY 9501 is designed according to the standard EN 55015 (CISPR 15). This balun is used to measure the attenuation of luminaires (lighting equipment) up to 1.605 MHz. Luminaire attenuation measurements require a 50 Ω…
Filters for power supply lines are measured according to CISPR 17, annex C (respectively DIN EN 55017, annex C). Two wideband transformers are required to transform the typical impedance of measurement devices from 50 Ω to 0.1 Ω or from…
The SY9223-120 is a balun including a resistive adaption part. It transforms an asymmetrical 50 Ω signal (N-connector) into a symmetrical 120 Ω environment (screw terminals). This balun can be used for transmission measurements according to IEC 61643-21. It is…
The isolation transformer corresponds to the wiring schematics of CISPR 13 Fig. A.2. It is equipped with a 50 Ω female N-connector at its input and a female 75 Ω N-connector at its output. Nominal Frequency range: 30 MHz –…