Material:Aluminium
Nominal Frequency Range (TEM-Mode):DC – 840 MHz
Usable Frequency Range (TEM and higher modes):DC – 1200 MHz
Septum Height:100 mm
Aperture:80 x 75 mm
Nominal Impedance:50 Ω
Standing Wave Ratio SWR typical:<1.05
Standing Wave Ratio SWR max.:< 1.2
Voltage / Fieldstrength relation:1 V = 10 V/m
Conversion Ratio Voltage ->Fieldstrength:+20 dB/m
Max. Input Power (with suitable termination):200 W
Maximum fieldstrength:1000 V/m
Transmission S21:< 0.1 dB
Connectors:N-female
Width x Length x Thickness:232 x 450 x 230 mm
Weight:2.0 kg