VOLVO MagTest 1 MHz

Requires a MagTest Software version 1.4.3 or higher. Testing up to 200 kHz is done with Multimeters. Testing 200 kHz to 1 MHz is done with R&S RTE Oscilloscope. Oscilloscope should be kept at least 1m away from LFPA as GPIB communication may get influenced. Therefore one longer GPIB cable is offered.

SW 9605 - Current Clamp was designed to measure RF-currents.

SW 9605 – Current Clamp

Insertion Loss in 50 Ω System: 34 dB

The SW 9605 Current Clamp was designed to measure RF-currents on conductors or conductor bundles with a maximum diameter of 23 mm. The conversion ratio is 1:1 in the nominal frequency range, therefore the receiver-reading in dBµV corresponds directly to the current in dBµA.

HHS 5206 – Circular Helmholtz Coils

HHS 5206-4 – Circular Helmholtz Coils

  • Number of turns: 4
  • Frequency Range: DC - 1.5 MHz
  • Coil Shape: Circular
  • Nominal Coil Current (continuous): 34 A
  • Maximum Coil Current (5 min.): 55 A
  • Magnetic Field Strength Nominal (continuos): 330 A/m
  • Magnetic Field Strength Maximum (5 min.): 530 A/m
  • Magnetic field strength at 1 A Coil Current: 9.64 A/m; 139.68 dBµA/m
  • Diameter/Side: 0.584 m
  • Resonance Frequency (pair of coils): 3000 kHz
HHS 5206 – Circular Helmholtz Coils

HHS 5206-16 – Circular Helmholtz Coils

  • Number of turns: 16
  • Frequency Range: DC - 500 kHz
  • Coil Shape: Circular
  • Nominal Coil Current (continuous): 33 A
  • Maximum Coil Current (5 min.): 55 A
  • Magnetic Field Strength Nominal (continuos): 1260 A/m
  • Magnetic Field Strength Maximum (5 min.): 2100 A/m
  • Magnetic field strength at 1 A Coil Current: 38.17 A/m; 151.63 dBµA/m
  • Diameter/Side: 0.6 m
  • Resonance Frequency (pair of coils): 700 kHz