The current sensor CP 9610 can measure up to 40 A in a frequency range from DC – 1 MHz. It is galvanically isolated and can withstand a maximum voltage of 210 VPK / VDC. The internal resistance of the conductive path is less than 3 mΩ, providing low power loss. The hall transducer is temperature compensated and allows high accuracy over temperature.
| Frequency Range: | DC – 1 MHz |
| Output Connector: | BNC (1 MΩ) |
| Current Sensing Range: | -40 A – +40 A 28Arms |
| Nominal conversion factor: | 50 mV/A |
| Internal Conductor Resistance: | < 3 mΩ |
| Typical Output Error: | ±3 % |
| Typical offset drift | ± 40mV |
| Dimension: | 105 x 44 x 115 mm |
| Typical Operation Time: | 24 h |
| EuT Connectors: | Wing terminals |
| Power Supply: | 3.7 V, 2.6 Ah Lithium Ion |
| Weight (incl. Battery): | 430 g |