AK 9515 G has extremely low losses in the complete frequency range combined with sufficient flexibility. AK 9515 G is especially applicable for radiated immunity or susceptibility measurements. As amplifier power is extremely expensive the attenuation of cables in field strength generating systems must be minimized.
The Inner Conductor consists of stranded wire (7 x 1.55 mm). The diameter of the inner conductor measures 4.5 mm. The outer conductor forms a double shielding by copper foil and copper meshwork. The low-loss dielectric consists of a foam-like PE-compound.
The Inner Conductor consists of stranded wire (7 x 1.55 mm). The diameter of the inner conductor measures 4.5 mm. The outer conductor forms a double shielding by copper foil and copper meshwork. The low-loss dielectric consists of a foam-like PE-compound.
Impedance: | 50 Ohm |
Capacitance: | 77 pF/m |
Fmax: | 6 GHz |
Shielding Effectiveness: | > 90 dB @ 1 GHz |
RF Peak Voltage: | 1 kV |
Outer Diameter: | 14.6 mm |
Bending Radius: | 150 mm |
Temperature Range: | -40 … 65 °C |
Standard-Connectors: | N-male, 7/16-male |