FESP 5133-F – Field Monitoring Coil

Schwarzbeck FESP 5133-F Field Monitoring Coil
Schwarzbeck FESP 5133-F Field Monitoring Coil

FESP 5133-F (rear view)
FESP 5133-F (rear view)
The Loop Sensor FESP 5133-F was designed to monitor the generated magnetic fields in radiated susceptibility tests. There is nearly no difference to the FESP 5133-7/41, which was originally designed for MIL-STD461E and previous versions, in which the RF-litz wire type AWG 7/41 was specified. Recent versions of MIL-STD 461 F and G require a resistance between 5 Ω to 10 Ω for the loop sensor instead. This new requirement was met by the use of a suitable RF-litz wire, which provides a resistance of 7.5 Ω for the FESP 5133-F.

Number of turns:36
Medium coil diameter:133 mm
Usable Freqency Range:0.01 kHz – 200 kHz
Resonance Frequency:~700 kHz
Inductance:~330 µH
Resistance:7.5 +/- 2 Ω
Capacitance:~157 pF
Weight:220 g
Mechanical Dimensions:136 x 177 x 36 mm
Mount:3/8″
Terminals:BNC
Standards:MIL-STD-461F; MIL-STD-461G